Description
Please Note: Only One Threaded Drain/Bleeder Port
The original Aqua-Flo XP2/XP2e wet end faceplate had 3 threaded drain/bleeder holes. Newer wet ends now come with only one threaded port. The other holes are molded into the plastic but do not have threads cut into them. If your installation needs more than one connection, you will need to tap the extra hole(s).
The Aqua-Flo XP2e pump wet end uses 1/4"-18 NPSM straight pipe threads for the drain plug opening. To add the threads, you will need a 1/4"-18 NPSM straight pipe thread tap. Carefully cut the threads by hand, keeping the tap straight and backing it out periodically to remove plastic shavings. Do not overtighten the drain plug when installing it.
Important: Use an NPSM straight-thread tap, not an NPT tapered-thread tap. The original drain plug uses an O-ring to create the seal.
This is a full XP2e wet end assembly for Aqua-Flo pumps, rated at 3.0HP with 2" x 2" plumbing connections (approximately 3" across threaded areas), featuring a 6.3" side discharge configuration designed for 56 frame applications. This assembly pairs with 56 frame motors rated at approximately 12.0 Amps on high speed with 230V power systems and is not compatible with 115v motors. Compatible with both single and dual speed motor configurations. The discharge outlet can be repositioned 90 degrees for flexible installation. This full assembly contains: volute housing, seal assembly, impeller, wear ring, suction cover, suction cover o-ring, drain plug with o-ring, and mounting hardware.
For installations requiring a barb fitting on the wet end face for auxiliary hose attachment, consider these options with or without sealing compound. Silicon sealant recommended for proper installation as pipe tape is not effective on these connections:
Barb Adapter, 3/8"b x 1/4"mpt, Pump Wet End Face fits Aqua-Flo & CMP
Barb Adapter, 3/8"b x 1/4"mpt, With Silicon Kit Pump Wet End Face fits Aqua-Flo & CMP
Important: Always verify horsepower selection based on motor amperage rating using the reference chart. 48 frame motors measure approximately 5 1/2" diameter with 1/4" thru-bolt heads spaced about 5 3/16" apart in cross pattern, while 56 frame motors measure approximately 6 1/4" diameter with 5/16" thru-bolt heads.